loading

Is specialized in designing, manufacturing for power transformers ,furnace transformers and reactor.

Cks Oil Type Series Reactor 6kv~35kv 600kvar~8000kvar-1705995350356393 1
Cks Oil Type Series Reactor 6kv~35kv 600kvar~8000kvar-1705995350356393 2
Cks Oil Type Series Reactor 6kv~35kv 600kvar~8000kvar-1705995350356393 3
Cks Oil Type Series Reactor 6kv~35kv 600kvar~8000kvar-1705995350356393 4
Cks Oil Type Series Reactor 6kv~35kv 600kvar~8000kvar-1705995350356393 5
Cks Oil Type Series Reactor 6kv~35kv 600kvar~8000kvar-1705995350356393 1
Cks Oil Type Series Reactor 6kv~35kv 600kvar~8000kvar-1705995350356393 2
Cks Oil Type Series Reactor 6kv~35kv 600kvar~8000kvar-1705995350356393 3
Cks Oil Type Series Reactor 6kv~35kv 600kvar~8000kvar-1705995350356393 4
Cks Oil Type Series Reactor 6kv~35kv 600kvar~8000kvar-1705995350356393 5

Cks Oil Type Series Reactor 6kv~35kv 600kvar~8000kvar-1705995350356393

Product Description

I.General description

Parallel capacitor banks are usually used in power system to compensate reactive power and improve power factor. In order to limit the passing current and closing inrush current of capacitor bank caused by higher harmonic current to protect the capacitor banks, series reactor is usually installed on the capacitor bank. Our  CKS oil type series reactor can work normally and continuously under the voltage peak value of 3 √ 2un terminal and 1.35in rated current, and can also operate continuously under the total current of no more than 35% of the third and fifth harmonic current, and the effective value is 1.2in rated current.

 

II.Structural features

1.The iron core is made of high-quality silicon steel sheet, wrapped with high-strength glass ribbon, thermally fixed, and fixed with special iron core curing paint, which can effectively reduce the vibration between iron core cakes and reduce the noise.

2.The coil is made of high quality paper wrapped copper wire. In order to ensure the safety and reliability of insulation structure, dot adhesive paper is used to prevent coil winding displacement.

3.The reactor adopts ripple oil tank with fully sealed structure. The thermal expansion and cold contraction of transformer oil are adjusted by the elasticity of ripple plate to ensure internal isolation from air, prolong service life and reduce maintenance.

 

III.Standard

GB 1094.1-1996 power transformers Part 1 General

GB 1094.2-1996 power transformers Part 2 temperature rise

GB 1094.3-2003 power transformers Part 3: insulation horizontal insulation test and external insulation air gap

GB 1094.5-2003 power transformers Part 5 short circuit withstand capability

JB / t5346-1998 series reactor

GB / t10229-1988 reactor

DL / t462-1992 technical conditions for ordering series reactors for high voltage shunt capacitors

IEC289-1988 reactor

 

IV. Model meaning

 

 

V.Environment

1. The altitude shall not exceed 2000m;

2. The operating environment temperature is - 25 ºC to + 45 ºC, and the relative humidity is not more than 90%;

 3. There is no harmful gas and inflammable and explosive materials around;

4.The surrounding environment should be well ventilated.

 

VI.Technical Parameters

Rated voltage:6kV,10kV,35KV

Frequency:50Hz,60Hz

Insulation grade:A

Insulation level:Li60AC25,Li75AC35,Li200AC85

 

 

Model
Capacitance capacity(Kvar)
Capacitor voltage (kV Reactance rate (%) terminal voltage(V) Rated current(A) Reactance(Ω) Oil weight(kg) Total weight(kg) Size mm(L*W*H)
CKS-36/11-6% 600 11/√3 6 381.1 31.5 12.1 50 240 670×500×900
CKS-54/11-6% 900 11/√3 6 381.1 47.24 8.07 65 280 725×500×910
CKS-72/11-6% 1200 11/√3 6 381.1 62.99 6.05 70 330 760×550×950
CKS-90/11-6% 1500 11/√3 6 381.1 78.74 4.84 78 380 810×610×980
CKS-108/11-6% 1800 11/√3 6 381.1 94.49 4.03 85 410 820×620×990
CKS-144/11-6% 2400 11/√3 6 381.1 125.98 3.02 100 510 830×670×1090
CKS-240/10-6% 4000 11/√3 6 381.1 209.92 1.815 175 820 890×710×1210
CKS-288/10-6% 4800 11/√3 6 381.1 251.9 1.513 200 990 1100×710×1210
CKS-360/10-6% 6000 11/√3 6 381.1 314.88 1.21 265 1210 1200×870×1320
CKS-396/10-6% 6600 11/√3 6 381.1 346.37 1.1 289 1410 1220×880×1410
CKS-480/10-6% 8000 11/√3 6 381.1 419.84 0.908 330 1410 1300×870×1550
CKS-540/10-12% 4500 12/√3 12 831.4 216.5 3.84 400 1680 1300×900×1610
CKS-600/10-12% 5000 12/√3 12 831.4 240.56 3.456 560 2250 1430×910×1640
CKS-720/10-12% 6000 12/√3 12 831.4 288.67 2.88 710 2690 1710×1010×1670
CKS-840/10-12% 7000 12/√3 12 831.4 336.78 2.469 830 2990 1820×1180×1710
CKS-960/10-12% 8000 12/√3 12 831.4 384.89 2.16 1050 3500 1970×1410×1800
Cks Oil Type Series Reactor 6kv~35kv 600kvar~8000kvarCks Oil Type Series Reactor 6kv~35kv 600kvar~8000kvarCks Oil Type Series Reactor 6kv~35kv 600kvar~8000kvar

 

    oops...!

    no product data.

    Go to homepage
    Leave us a message
    We Welcome Custom Designs And Ideas And Is Able To Cater To The Specific Requirements. For More Information, Please Visit The Website Or Contact Us Directly With Questions Or Inquiries.
    Related Products
    no data
    Copyright © 2024 NINGBO VILLE ENTERPRISE CO.,LTD. - https://www.villeelectric.com/ | Sitemap
    Customer service
    detect