loading

Is specialized in designing, manufacturing for power transformers ,furnace transformers and reactor.

Vltr Power Plant Electric Traction Transformer with Toroidal Coil Stucture 1
Vltr Power Plant Electric Traction Transformer with Toroidal Coil Stucture 2
Vltr Power Plant Electric Traction Transformer with Toroidal Coil Stucture 3
Vltr Power Plant Electric Traction Transformer with Toroidal Coil Stucture 4
Vltr Power Plant Electric Traction Transformer with Toroidal Coil Stucture 5
Vltr Power Plant Electric Traction Transformer with Toroidal Coil Stucture 6
Vltr Power Plant Electric Traction Transformer with Toroidal Coil Stucture 1
Vltr Power Plant Electric Traction Transformer with Toroidal Coil Stucture 2
Vltr Power Plant Electric Traction Transformer with Toroidal Coil Stucture 3
Vltr Power Plant Electric Traction Transformer with Toroidal Coil Stucture 4
Vltr Power Plant Electric Traction Transformer with Toroidal Coil Stucture 5
Vltr Power Plant Electric Traction Transformer with Toroidal Coil Stucture 6

Vltr Power Plant Electric Traction Transformer with Toroidal Coil Stucture

asic Info.

Model NO.
VLTR
Usage
Single-phase Transformer
Frequency Characteristics
High Frequency
Shape of Core
Ring
 
 
Standard
IEC Standard
Capacity
10000kVA
Connection
Yd11
Rated Voltage
35kv
Transport Package
Wooden Case
Specification
According to specification
Trademark
VILLE
Origin
China
HS Code
8504231200
Production Capacity
1000 Sets/Year

Product Description

Specifications:
ZHS Series Oil immersed Rectifier Transformer:Toroidal coil stucture, loss, Low noise, Low partial discharge, no
leakage.

Rectifier transformers are combined with a diode or thyristor rectifier.The applications range from very large
aluminum electrolysis to various small and medium size operations.The transformers may have a built-in or
separate voltage regulation unit for direct output regulation of diode rectifiers, and correspondingly a power
factor improvement with a thyristor rectifiers.

Features:
1) Low loss
2) Low noise
3) High efficiency
4) Low partial discharge
5) Strong mechanical strength and short-circuit withstand ability.
6) Operation reliability
7) Easy maintenance
8) Pretty outline and compact structure
9) 100% guaranteed no leakage

Brief specification:
1) Voltage class:6~110 KV
2) Capacity:630 kVA to 120, 000 kVA
3) Short-circuit impedance:4.5~21%
Losses:No-load losses is fully comply with IEC standard requirements

Application:
1) Aluminum smelting
2) Magnesium smelting
3) Copper smelting
4) Zinc smelting
5) The largest installations are those for aluminum electrolysis with several transformer/rectifier units in parallel 
    operation to achieve the required DC current, in all cases the rectifier can be with diodes or thyristors.

Technical parameters:
Type Rated Power (kVA) Rated Voltage (Line Side)  
V
Rated Voltage (Valve Side)
V
Connection Symbol Active Part Weight (kg) Oil Weight (kg) Total Weight
(kg) 
Overall
Dimension (L*W*H) (mm)
 ZSSP-800/10  800  10000  400  Dyn11  1580  660  3240  2160*1625*1855
 ZSSP-2000/35  2000  35000  400  Yyn0  3320  1280  5735  2600*1260*2740
   ZSSP-4000/35  4000  35000  950  Dd0y11  5410  2040  9540  2570*1745*2720
  ZSSP-6300/35  6300  35000  1000  D(  ±7.5  °)dyn 8600   4860  18260  3340*1875*3370
  ZSSP-7000/35   7000  35000  950  Dd0y11  8570  3390  14700  3185*985*3475
   ZSSP-8000/22  8000  22000  950   Dd0y11  8640  3340  14710 3210*1905*3375 
   ZSSP-8000/35  8000  35000  950  Dd0y11    9170  3590  15520  3340*1870*3490
  ZSSP-9000/35  9000  35000  950   Dd0y11  9920  4070  15740  3240*1915*3720
  ZSSP-10000/35  10000 35000   1000   D(  ±7.5  °)dyn  11090  4400  18850 3410*1915*3845
Railway balance traction transformer is the main transformer in the traction substation of railway electrification. It
is suitable for traction electrification performance characters, such as short-time serious over-load, 3-phase
unbalanced load, frequent close to earth short-circuit, etc. It has the distinguishing features of low loss, high
mechanical strength, simple structure, convenient manufacture. Because of traction transformer's long working
in no-load condition, the proportion of no-load loss to load loss is selected reasonable in order to be in
transformer economic performance during designing.
 
Technical Parameters of 110kv class YN.A Connection Balance Traction Transformer
Rated Capacity
(kVA)
Voltage Combination No-load loss
(KW)
Load los s(KW) No-load current
(%)
Short circuit impedance
(%)
Vector Group Total weight(kg) Overall Dimension(mm)
H.V.(kv) Tapping range L.V.(KV) Active part Oil weight Total weight L W  H
10000 110 ±2×2.5% 27.5×2 12.5 59 0.9 10.5 or 8.4 YNA 13300 8900 31800 5430×2905×4030
12500 14.5 70 0.9 15670 9800 32000 6060×3100×4380
16000 16.5 86 0.6 18860 10100 36160 6170×3450×4450
20000 20.0 104 0.6 22290 10600 39900 6260×3620×4670
25000 25.0 123 0.55 26350 11200 47200 6320×3920×4835
31500 29.0 148 0.50 38500 12200 53000 6450×4130×5040
40000 35.0 174 0.45 46060 13600 66000 6600×4320×5200
50000 41.0 216 0.40 54450 17200 73000 6830×4500×5400
63000 50.0 260 0.35 64750 19800 86000 6990×4880×5600
Note:
1.The above product can be produced according to the highland type, and the products with other power can be supplied
2.the above data is for reference only, our company reserves the right of product renewing, amendment and design. If you have specific matters, please contact with our company

 

 

    oops...!

    no product data.

    Go to homepage
    Leave us a message
    We Welcome Custom Designs And Ideas And Is Able To Cater To The Specific Requirements. For More Information, Please Visit The Website Or Contact Us Directly With Questions Or Inquiries.
    Related Products
    no data
    Copyright © 2024 NINGBO VILLE ENTERPRISE CO.,LTD. - https://www.villeelectric.com/ | Sitemap
    Customer service
    detect