Product introduction:
Isolation transformer is refer to the input winding and an output winding with electrical isolation transformer,the transformer isolation used to
avoide accidental and the touch of a charged body,isolation transformer is isolated,former vice winding coils of the respective current,the
primary side and secondary side of the electrical insulation and also make the loop isolation.In addition,the characteristics of the iron core
loss at high frequency,thereby inhibiting high-frequency clutter was introduced into the control loop.
The transformer is a three-phase single phase,iron core dry type.
After the winding and the iron core are assembled into a whole,the coil and the iron core are firmly integrated into a whole,and the noise of
the running time is greatly reduced.
Compared with the similar products in China,the transformer has the advantages of beautiful appearance and the like,can replace the well-
known brands at home and abroad.Product use:
1.The power input terminal access isolation transformer(triangle/star)2.
2.If grid the third harmonic and interference signal is serious,use /Y connection group isolation transformer can be removed three times
harmonics and reduce the signal interference.
3.Can use /Y connection group isolation transformer to produce new neutral line,make equipment and network neutral line has nothing
to do,to avoide due to network neutralline caused by poor equipment operation is not normal
4.Current waveform distortion caused by nonlinear loads(e.g.,three harmonics) can be isolated without polluting the power grid.
5.On the power ouput end of the isolation transformer(star/delta)
6.Current distortion of the non-linear load is prevented,and the normal operation of the regulated power supply and the back to the electric
network are affected.
7.Nonlinear load current distortion effects of sampling accuracy can be in Y/delta connection group isolation transformer input sampling.It
can reflect the actual situation with the control signal and the voltage stabilizing power supply control normal.
8.If the load is not balanced,the normal work of using Y/delta connection group does not affect the power supply.
Use environment:
Not more than 2000 meters above the sea level.Operation ambient temperature-25ºC~+60ºC,the relative humidity is not more than 90%.No
toxic gas around,no inflammable and explosive articles.Surrounding environment should have good ventilation conditions,such as installed in
the cabinet,should be the installation of ventilation equipment.
Technical parameter:
Input rated voltage:220V~1200V;
Output rated voltage:220V~1200V;
Operating frequency:50/60Hz;
Anti electric strength:iron core winding
3000VAC/50Hz/5mA/10S
No arcing breakdown
Insulation resistance:1000VDC insulation resistance is greater than or equal to 100MΩ
Reactor noise:less than 65Db(1meters test with reactor level)
Protection level:IP00
Insulation class:H level or above
Efficiency:more than 95%